Verified product-page source (readable static HTML text snapshot) Source: https://www.westernstatescat.com/power-systems/electric-power/diesel-generator-sets/3516c-60-hz-1650-2500-kw-diesel-generator/ Original HTML SHA-256: 32b5f475da4cb05b11fd75ab8efdcf109318dbecd9dfb6ccc4aebb96497bd5e2 3516C (60 HZ) | 1650-2500 kW Diesel Generator « Go back to Electric Power Images 360 View of Exterior View Full Spec Document Request Info Request Info 3516C (60 HZ) | 1650-2500 kW Diesel Generator Contact Us For Price SPECS SUMMARY Standby Rating 2500/2250/2000 ekW Prime Power Rating 2250/2045/1825 ekW Emissions/Fuel Strategy U.S. EPA Cert., Tier 2 Voltage 380 to 13800 Volts Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications Benefits and Features Standard / Optional Equipment Specifications Standby Rating 2500/2250/2000 ekW Prime Power Rating 2250/2045/1825 ekW Emissions/Fuel Strategy U.S. EPA Cert., Tier 2 Voltage 380 to 13800 Volts Frequency 60 Hz Speed 1800 rpm Duty Cycle Standby, Mission Critical, Prime, Continuous Maximum Rating 2500 ekW Minimum Rating 1650 ekW Engine Model 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel Bore 6.69 in (170 mm) Stroke 7.48 in (190 mm) Stroke - HD 8.46 in (215 mm) Displacement 4764.73 in (78 l) Compression Ratio 14.7:1 Aspiration TA Fuel System Electronic unit injection Governor Type Adem™3 Length - Minimum 266.2 in (6761 mm) Length - Maximum 276.3 in (7019 mm) Width - Minimum 92.1 in (2339 mm) Width - Maximum 92.1 in (2339 mm) Height - Minimum 118 in (2997 mm) Height - Maximum 118 in (2997 mm) Dry Weight - Genset (minimum) 35880 lb (16275 kg) Dry Weight - Genset (maximum) 38780 lb (17590 kg) Benefits and Features Cat Generator Set Package Cat generator set packages have been fully prototype tested Accepts 100% block load in one step and meets NFPA 110 loading requirements Conform to ISO 8528-5 steady state and transient response requirements Cat Diesel Engine Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight SR5 Alternator Superior motor starting capability minimizes need for oversizing alternator Designed to match performance and output characteristics of Cat diesel engines Robust Class H insulation Cat ECS Control Panel User-friendly interface and navigation Scalable system to meet a wide range of installation requirement Expansion modules and site-specific programming for specific customer requirements Cooling System Designed to operate in standard ambient temperatures up to 50°C (122°F) Contact your Cat Dealer for specific ambient and altitude capabilities Certifications UL 2200 Listed CSA IBC seismic certification OSHPD pre-approval One Safe Source Components used in the generator set are selected at the design stage to provide optimum package performance The generator set is fully assembled at a Caterpillar facility following our quality guidelines Each generator set package is tested before leaving the Caterpillar facility Cat product support, including dealer service, parts and warranty covers the entire Cat power system World Wide Product Support Cat dealers have over 1,800 dealer branch stores operating in 200 countries Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements Standard Equipment Air Inlet System Air cleaner; single element canister type Cooling Package mounted radiator Exhaust Exhaust flange outlet Control Panels Communications: Reverse reactive power (kVAr) (32RV) Customer data link (Modbus RTU) Generator mounted - rear facing 1 Programmable digital outputs Auto/start/stop control - Serial annunciator module data link Engine cool-down timer 24 Volt DC operation Controls: Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor Alarm acknowledge Cat connect Engine cycle crank Text alarm/event descriptions Overcurrent (50 / 51) Accessory module data link Cat ECS 100 1 Programmable relay outputs (Form C) Emergency stop pushbutton Speed adjust 4 Programmable relay outputs (Form A) Number of I/O varies on options selected 6 Customer programmable digital inputs Environmental sealed front face Load histogram feature Lamp test PLC functionality Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy Digital indication for: Operating hours RPM DC volts Frequency (Hz) Coolant temperature Volts (L-L & L-N) Oil pressure (psi, kPa or bar) Amps (per phase & average) kVAr (per phase, average & percent) kVA (per phase, average & percent) kW (per phase, average & percent) Power factor (per phase & average) kW-hr (total) kVAr-hr (total) High coolant temperature Overspeed Failure to start (overcrank) Warning/shutdown with common LED indication of shutdowns for: Emergency stop Low oil pressure Low coolant level Low coolant temperature Programmable protective relaying functions: Over/under frequency (81 o/u) Generator phase sequence Over/under voltage (27 / 59) Reverse power (kW) (32) Fuel Primary fuel filter with integral water separator Generator Matched to the performance and output characteristics of Cat engines IP23 Protection Power Termination Busbar Control Panel Cat ECS Genset controller Cooling System Certified standard PGS provided Exhaust System Flanged faced outlet(s) Dry exhaust manifold Fuel System Flexible fuel lines - shipped loose Fuel cooler; not included with packages without radiator Secondary fuel filters Fuel priming pump General Caterpillar yellow with high gloss black rails and radiator Right hand servicing Flywheel and flywheel housing - SAE No. 00 Paint - Caterpillar yellow except rails and radiators gloss black SAE standard rotation Generator and Attachments Busbar connections, top center mounted, top cable entry Class H temperature rise at 40C ambient (125C prime / 150C standby) Low voltage: NEMA standard hole pattern Medium voltage: Anti-condensation space heater 6 Lead Random wound Form wound NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby) Permanent magnet excitation (PMG) Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby) Internal excitation (IE) 3 Phase brushless, Salient pole High voltage: Winding temperature detectors Busbar connections, right side extension box, bottom cable entry Governing System ADEM A3 Literature Parts book Lubrication System Lubricating oil Fumes disposal Integral lube oil cool Oil drain lines and valve Oil filter, filler and dipstick Gear type lube oil pump Mounting System Anti-vibration mounts (shipped loose) Rubber anti-vibration mounts - shipped loose Rails - engine/generator/radiator mounting Starting System Battery disconnect switch 45 Amp Charging alternator 24 Volt electric starting motor Battery and battery rack w/cables Optional Equipment Control System EMCP 4.4 Exhaust Exhaust mufflers Air Inlet System Single element filter Dual element air cleaner Generator Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE) Oversize and premium generators Anti-condensation heater Cooling System Coolant Standard ambient ATAAC radiators Optional installed radiators Optional installed ATAAC radiators Standard ambient radiators Water level switch gauges Power Termination Circuit breakers, UL listed Circuit breakers, IEC compliant Crankcase System Explosion relief valves Ventilation system No explosion relief valves Control Panels Load share module Digital I/O module Generator temperature monitoring & protection Remote monitoring software Mounting Rubber anti-vibration mounts IBC isolators Exhaust System Y Adapters Flexible fittings Exhaust offset Tier 4 clean emissions module Elbows Flange and exhaust expanders Tier 4 clean emission MOD Kits Tier 4 dosing cabinet Flanges Mufflers Clean emission parts Starting/Charging Oversize batteries Battery chargers Charging alternator Air starting motor with control and silencer Heavy duty starting system Fuel System Primary fuel filter General The following options are based on regional and product configuration: UL 2200 package CSA Certification EEC Declaration of Conformity Special paint (Colors other than Caterpillar yellow or high performance paints) Integral & sub-base fuel tanks US aid emblem Enclosures: Sound attenuated, weather protective Automatic transfer switches (ATS) Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007 EU Certificate of Conformance (CE) Integral & sub-base UL listed dual wall fuel tanks Generators and Attachments High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame Thermostat for space heater Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame Differential current transformers (DCT) 8.7 kV and 15 kV classes Generator conversion Space heater kit Alternator air cleaner Instrumentation Pyrometer and thermocouples Lubrication System Oil level regulator Lube oil in standard sump Prelube pumps Mounting System Puck style low efficiency isolators Spring type vibration isolators IBC vibration isolators Power Connections Ground cables between generator and terminal box Neutral ground connections Left side power connections Center post busbars Right side power connections 2700 Frame, four lead, four terminal Rear power connections Low voltage Circuit breakers Special Tests / Reports IBC Certification Fuel consumption test Generator test report PGS Test report @ 1.0 power factor Torsional vibration analysis reports OSHPD Certification Generator set fuel consumption test PGS Test report @ 0.8 power factor Standard engine test charge Canadian Standards Association certification Starting and Charging Air pressure regulator Starter cover Air starting motors 10, 20, 35 and 50 Amp Battery chargers Electric starting motors Jacket water heaters 24 Volt battery set - Dry Engine barring device Extended Service Coverage Platinum, Gold and Silver coverage