Verified product-page source (readable static HTML text snapshot)
Source: https://h-cpc-stage.cat.com/cmms/v2?f=product&it=product&cid=402&lid=en&sc=US&gid=18260932&pid=18331497&nc=1
Original HTML SHA-256: a7c7afa100e486aa612a09bbc7003fb1f3a5f3a891a7f75cd3d5649d3f351236
/ Power Systems / Electric Power / Diesel Generator Sets
C27 (60 Hz)
C27 (60)
Overview
Specifications
Benefits & Features
Equipment
Related Products
Overview
The C27 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 680 to 800 ekW at 60 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and to take on 100% block load. The C27 is certified as a low fuel consumption system as well as having a certificate for EPA Stationary Emergency (Tier 2). Seismic certification is also available for selected models, ensuring your generator sets are equipped for that unexpected disturbance. The integrated control system, including ATS and switchgear, ensures a consistent power supply and connection to your fleet through on-site and remote monitoring options. The GCCP 1.2 control panel features a user-friendly interface and puts your management and diagnostics tools in one location. The optional ECS 200 controller provides multi generator set paralleling capability, allowing you to use multiple generator sets for increased power output and improved reliability. It's not just quality that matters but customization, choose from a broad range of accessories and bolt-on system expansion attachments. Discover our upgradeable packaging options to work with your spatial restrictions and environmental conditions. Our C27 generator sets are developed for such prerequisites, so that you can meet your specific power needs. Build in additional safety features with the UL 2200 (3rd Edition) and CSA certified package options.
To watch these videos, you will need to accept the use of targeting cookies. Cookies
Specifications
Units: US
Standby Rating 750/800 ekW
Prime Power Rating 680/725 ekW
Emissions/Fuel Strategy Low BSFC / U.S. EPA Tier 2 Certified
See more
Benefits & Features
Cat Generator Set Package
Cat generator set packages have been fully prototype tested
Accepts 100% block load and meets NFPA 110 loading requirements with G3 Class load acceptance capability
Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
Reliable, rugged, durable design
Field-proven in thousands of applications worldwide
Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
Superior motor starting capability minimizes need for oversizing alternator
Designed to match performance and output characteristics of Cat diesel engines
Robust Class H insulation
See more
Docs & Links
Electric Power Ratings Guide
C27, 60 Hz, 750 ekW Standby 680 ekW Prime, Low Fuel Consumption Spec Sheet
C27, 60 Hz, 750 ekW Standby 680 ekW Prime, U.S. EPA Emergency Stationary (Tier 2) Spec Sheet
C27 Electric Power Ratings
To watch these videos, you will need to accept the use of targeting cookies. Cookies
Docs & Links
Electric Power Ratings Guide
C27, 60 Hz, 750 ekW Standby 680 ekW Prime, Low Fuel Consumption Spec Sheet
C27, 60 Hz, 750 ekW Standby 680 ekW Prime, U.S. EPA Emergency Stationary (Tier 2) Spec Sheet
C27 Electric Power Ratings
October 27, 2026
Specifications
Units: US
Generator Set Specifications
Standby Rating 750/800 ekW
Prime Power Rating 680/725 ekW
Emissions/Fuel Strategy Low BSFC / U.S. EPA Tier 2 Certified
Voltage 208 to 600 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby, Prime
Engine Specifications
Engine Model C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel
Bore 5.4 in
Stroke 6 in
Displacement 1649.47 in³
Compression Ratio 16.1:1
Aspiration TA
Fuel System MEUI
Governor Type Adem™A4
Generator Set Dimensions
Length - Maximum 184 in
Width - Maximum 67.8 in
Height - Maximum 85.1 in
Benefits & Features
Cat Generator Set Package
Cat generator set packages have been fully prototype tested
Accepts 100% block load and meets NFPA 110 loading requirements with G3 Class load acceptance capability
Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
Reliable, rugged, durable design
Field-proven in thousands of applications worldwide
Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
Superior motor starting capability minimizes need for oversizing alternator
Designed to match performance and output characteristics of Cat diesel engines
Robust Class H insulation
GCCP and CAT ECS
User-friendly interface and navigation
Scalable system to meet a wide range of installation requirement
Expansion modules and site-specific programming for specific customer requirements
Cooling System
Designed to operate in standard ambient temperatures up to 55°C (131°F)
Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
UL 2200
CSA
IBC seismic certification
OSHPD pre-approval
One Safe Source
Components used in the generator set are selected based on seamless design integration to provide the optimum performance
The generator set is fully assembled at a Caterpillar facility following our quality guidelines
Each generator set package is tested before leaving the Caterpillar facility
Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
Cat dealers have over 1,800 dealer branch stores operating in 200 countries
Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Standard Equipment
Air Inlet
Air cleaner; single element canister type with service indicator
Control Panel
GCCP 1.2
Digital Indicators
Warning/shutdown Indicators
Programmable protective relaying functions
Communications
Features include:
Cooling System
Coolant level sensor
Coolant drain line with valve terminated on edge of base
ATAAC
Caterpillar extended life coolant
Radiator sized to 50 degrees C
Fan and belt guards drive
Exhaust System
203 mm (8 in) ID round flanged outlet
Exhaust manifold - dry
Fuel System
Primary fuel filter with integral water separator
Electric fuel priming pump
Fuel cooler
Flexible fuel lines - installed
Secondary fuel filters
Generators and Attachments
Integrated voltage regulator (IVR) includes
For EPA Stationary Emergency (EPA Tier 2 Emissions) configurations:
Busbar connections:
SR5 Permanent magnet excitation (PMG) (PM)
For Low BSFC configurations:
Lube System
Standard volume oil pan - 68 Ltr
Lubricating oil
Oil drain lines and valve
Gear type lube oil pump
Oil filter, filler and dipstick
Fumes disposal - open crankcase ventilation routed to front of package
Integral lube Oil cooler
Mounting System
Rubber anti-vibration mounts - shipped loose
Rails - engine/generator/radiator mounting
Starting and Charging System
24-Volt electric starting motor
Battery, rack and cables - shipped-loose
Battery disconnect switch
Charging alternator 45A
General
Paint - Caterpillar yellow with high gloss black rails & radiator
SAE standard rotation
Right hand servicing
Flywheel and flywheel housing-SAE No. 0 and SAE No. 18
Optional Equipment
Air Inlet System
Standard air cleaners
Heavy duty air cleaners
Dual element air cleaners
Starting / Charging System
20 Amp enclosure Battery chargers
10 Amp Battery chargers
24 Volt battery set - Dry
Air starting motor with control and silencer
Space heater
24 Volt electric start motors - Heavy duty
Jacket water heaters
Circuit breakers
400, 800, 1200, 1600, 2000, 2500, 3000 Amp, 3 pole, UL-100% rated Circuit breakers
2000 Amp, 3 pole, IEC rated Circuit breakers
800 Amp, 4 pole, IEC rated Circuit breakers
Control Panels
Cable shroud - Bottom mounted
Cable shroud - Top mounted
CAT ECS 200
Side extension box
Remote annunciator module
Auxiliary box options
Remote mounted panel harness mounting kit
Remote mounted circuit breaker terminals
Modbus monitor local packages
Remote DIO module
Cat connect telematics
Load share module
Vandal proof panel cover
Installed DIO module
Remote mounting harness
Annunciator modules
Cooling System
Radiator duct flange
High ambient radiator
Extended life coolant
Certified radiator
Standard radiator
Enclosures
Enclosure louvers
Enclosure with lifting base or fuel tank
Panel bracket
AC distribution panel, lights and outlet
Enclosure lighting
Enclosure colors
Special Sound attenuated enclosure
Enclosure fuel tank options
Cold weather bundle
Exhaust System
Mufflers
Elbows
Flanges
Exhaust through the wall kit
Flexible fittings
Guard and shield system
Generator and Attachments
60 Hz standard generators
60 Hz premium generators
Lube System
Prelube pumps
Oil level regulator
Mounting System
Mounting base type
IBC vibration isolators
Puck style low efficiency isolators
Spring type vibration isolators
Power Connections
Center post busbars
Cable entry - right/left/rear
Neutral grounding connection
Power connections - Right / Left / Rear
Special Tests / Reports
Torsional vibration analysis report
Generator test report
IBC seismic Certifications
OSHPD seismic Certifications
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
Special CSA test Certification
Standard engine test
General
Miscellaneous inspection
US aid emblem
Special paint
SGS Inspection
Related Products
Units: US
Electric Power Controls
Model
EMCP 4.2 Control Panel
View 360