Verified product-page source (readable static HTML text snapshot) Source: https://www.jenbacher.com/en/gas-engines/type-4/j412/ Original HTML SHA-256: 10db96ab8ecce0e19b8534ac075f6ebb3ae943987f713b7691fb84df40b1f5a6 Other Engine Types Jenbacher J412 Details Balance of Plant Case Studies The J412 is a part of the efficient Type 4 engines family, a V12-cylinder power generation solution. A high-efficient combined heat and power solution used in medium-size businesses across multiple industries. Back to Jenbacher Type 4 Other Type 4 models: j416 / up to 1,249 kW j420 / up to 1,694 kW Genset CHP Module Container Change the scope of supply by clicking on a thumbnail. Scope of supply: Generator Set CHP Module Container * Provided technical data is for information only. Data ranges are calculated considering various gas quality levels and ambient conditions (standard or hot/tropical conditions, etc.). Jenbacher can change the technical data unilaterally. In the case of such change, we will update the data on our pages as soon as we can. Please reach out to our experts to get help with engines selection, obtain the technical parameters for your gas composition. Output and efficiency at generator terminals. Energy input is according to DIN ISO 3046 and DIN 6271, respectively, with a tolerance of + 5%. All data according to full load and subject to technical development and modification. Based on emission values of 250 and 500 mg/Nm3 NOx at 5% O2 at dry exhaust gas. Base for biogas and sewage gas versions: 65% CH4 / 35% CO 2 . Base for landfill gas version: 55% CH4 / 40% CO 2 / Rest N2. 50 Hz 60 Hz - Any Fuel Type - Bio-, Sewage-, Landfill Gas Coal Mine Gas Natural Gas Associated Petroleum Gas (Flaregas) Electrical Output up to 935 kW Thermal Output up to 1114 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 43.6 % Thermal Efficiency up to 50.3 % Electrical Output up to 935 kW Thermal Output up to 930 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 43.5 % Thermal Efficiency up to 43.4 % Electrical Output up to 902 kW Thermal Output up to 928 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 43.4 % Thermal Efficiency up to 44.6 % Electrical Output up to 935 kW Thermal Output up to 1,114 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 43.6 % Thermal Efficiency up to 50.3 % Electrical Output up to 902 kW Thermal Output up to 983 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 42.4 % Thermal Efficiency up to 46.2 % L: 5,400 x W: 1,800 x H: 2,200 mm - Any Fuel Type - Bio-, Sewage-, Landfill Gas Coal Mine Gas Natural Gas Associated Petroleum Gas (Flaregas) Electrical Output up to 853 kW Thermal Output up to 1,003 kW Voltage 480V, 4.16kV, 6.6KV Electrical Efficiency up to 41.7 % Thermal Efficiency up to 47.9 % Electrical Output up to 853 kW Thermal Output up to 956 kW Voltage 480V, 4.16kV, 6.6KV Electrical Efficiency up to 41.2 % Thermal Efficiency up to 44.8 % Electrical Output up to 853 kW Thermal Output up to 1,003 kW Voltage 480V - 13.8kV Electrical Efficiency up to 41.7 % Thermal Efficiency up to 47.9 % Electrical Output up to 853 kW Thermal Output up to 1,003 kW Voltage 480V, 4.16kV, 6.6KV Electrical Efficiency up to 41.7 % Thermal Efficiency up to 47.9 % Electrical Output up to 853 kW Thermal Output up to 982 kW Voltage 480V - 13.8kV Electrical Efficiency up to 41.4 % Thermal Efficiency up to 47.7 % L: 220 x W: 75 x H: 90 inches 50 Hz 60 Hz - Any Fuel Type - Bio-, Sewage-, Landfill Gas Coal Mine Gas Natural Gas Associated Petroleum Gas (Flaregas) Electrical Output up to 935 kW Thermal Output up to 1114 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 43.6 % Thermal Efficiency up to 50.3 % Electrical Output up to 935 kW Thermal Output up to 930 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 43.5 % Thermal Efficiency up to 43.4 % Electrical Output up to 902 kW Thermal Output up to 928 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 43.4 % Thermal Efficiency up to 44.6 % Electrical Output up to 935 kW Thermal Output up to 1,114 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 43.6 % Thermal Efficiency up to 50.3 % Electrical Output up to 902 kW Thermal Output up to 983 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 42.4 % Thermal Efficiency up to 46.2 % L: 6,000 x W: 1,800 x H: 2,200 mm - Any Fuel Type - Bio-, Sewage-, Landfill Gas Coal Mine Gas Natural Gas Associated Petroleum Gas (Flaregas) Electrical Output up to 853 kW Thermal Output up to 1,003 kW Voltage 480V, 4.16kV, 6.6KV Electrical Efficiency up to 41.7 % Thermal Efficiency up to 47.9 % Electrical Output up to 853 kW Thermal Output up to 956 kW Voltage 480V, 4.16kV, 6.6KV Electrical Efficiency up to 41.2 % Thermal Efficiency up to 44.8 % Electrical Output up to 853 kW Thermal Output up to 1,003 kW Voltage 480V - 13.8kV Electrical Efficiency up to 41.7 % Thermal Efficiency up to 47.9 % Electrical Output up to 853 kW Thermal Output up to 1,003 kW Voltage 480V, 4.16kV, 6.6KV Electrical Efficiency up to 41.7 % Thermal Efficiency up to 47.9 % Electrical Output up to 853 kW Thermal Output up to 982 kW Voltage 480V - 13.8kV Electrical Efficiency up to 41.4 % Thermal Efficiency up to 47.7 % L: 240 x W: 75 x H: 90 inches 50 Hz 60 Hz - Any Fuel Type - Bio-, Sewage-, Landfill Gas Coal Mine Gas Natural Gas Associated Petroleum Gas (Flaregas) Electrical Output up to 935 kW Thermal Output up to 1114 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 43.6 % Thermal Efficiency up to 50.3 % Electrical Output up to 935 kW Thermal Output up to 930 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 43.5 % Thermal Efficiency up to 43.4 % Electrical Output up to 902 kW Thermal Output up to 928 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 43.4 % Thermal Efficiency up to 44.6 % Electrical Output up to 935 kW Thermal Output up to 1,114 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 43.6 % Thermal Efficiency up to 50.3 % Electrical Output up to 902 kW Thermal Output up to 983 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 42.4 % Thermal Efficiency up to 46.2 % L: 12,200 x W: 3,000 x H: 2,700 - 5,300 mm - Any Fuel Type - Bio-, Sewage-, Landfill Gas Coal Mine Gas Natural Gas Associated Petroleum Gas (Flaregas) Electrical Output up to 853 kW Thermal Output up to 1,003 kW Voltage 480V, 4.16kV, 6.6KV Electrical Efficiency up to 41.7 % Thermal Efficiency up to 47.9 % Electrical Output up to 853 kW Thermal Output up to 956 kW Voltage 480V, 4.16kV, 6.6KV Electrical Efficiency up to 41.2 % Thermal Efficiency up to 44.8 % Electrical Output up to 853 kW Thermal Output up to 1,003 kW Voltage 480V - 13.8kV Electrical Efficiency up to 41.7 % Thermal Efficiency up to 47.9 % Electrical Output up to 853 kW Thermal Output up to 1,003 kW Voltage 480V, 4.16kV, 6.6KV Electrical Efficiency up to 41.7 % Thermal Efficiency up to 47.9 % Electrical Output up to 853 kW Thermal Output up to 982 kW Voltage 480V - 13.8kV Electrical Efficiency up to 41.4 % Thermal Efficiency up to 47.7 % L: 480 x W: 120 x H: 110 - 200 inches CONSULT AN EXPERT Back to Jenbacher Type 4 Other Type 4 models: j416 / up to 1,249 kW j420 / up to 1,694 kW Product Details Resources Jenbacher Type 4 engines have the same design, emissions control, and waste gas-to-energy capabilities as their Type 2 and Type 3 counterparts, plus high power density and strong efficiency performance within their power range. The high-power turbocharger allows operation at higher air intake temperature and altitude. A four-valve cylinder head features enhanced swirl and channel geometry using calculation and simulation methods, resulting in improved cooling and combustion conditions. The Type 4’s connecting rod reduces bearing wear and is easy to maintain. Applicable gas types include: natural gas, associated petroleum gas (flare gas), propane, biogas, sewage gas, landfill gas, coal mine gas, and other special gases (e.g. coke, wood, and pyrolysis gases). Widely used for natural gas, biogas and associated petroleum gas applications. Scope of supply: Generator Set CHP Module Container Scope of supply, dedicated for applications, which require power generation only. If you are looking for simultaneous power and heat generation, please consider Combined Heat and Power Module ( CHP Module ) scope of supply. Minimum scope of supply for genset: Engine and alternator installed on the frame Control panel Gas train The scope of supply can be extended further with various balance of plant options (BOP), reach out to our specialists for help in selecting scope of supply and BOP options to fulfill your project’s needs. Gensets can be installed inside a building or inside a container. To see more details about our containerized solutions, click here . Combined Heat and Power Module ( CHP Module ) solutions allow customers to generate power and heat simultaneously at a high total efficiencies, reaching up to 95%. Usual scope of supply: Engine and alternator installed on the frame Control panel, gas train Heat exchangers including exhaust gas heat exchanger CHP Modules can generate hot water or steam at various parameters and can be integrated with your existing heat infrastructure. You can select the option that fits your project’s needs among the various heat recovery schemes provided by Jenbacher. The scope of supply can be extended further with various balance of plant options (BOP), reach out to our specialists for help in selecting scope of supply and BOP options to fulfill your project’s needs. CHP Modules can be installed inside a building or inside a container. To see more details about Jenbacher’s containerized solutions, click here . Jenbacher’s containerized solutions are “ready-to-use” power plants, allowing customers to reduce commissioning time. Jenbacher has produced containerized power plant solutions for decades, providing customers with innovative power generation technologies wrapped in well-designed, dependable packages. Both genset and CHP module solutions can be supplied as containerized versions depending on your needs. Usual scope of supply: Engine and alternator installed on the frame Control panel, gas train Container with integrated ventilation system Cooling systems Lube oil supply system Exhaust gas heat exchanger (for CHP module) The scope of supply can be extended further with various balance of plant options (BOP), reach out to our specialists for help in selecting scope of supply and BOP options to fulfill your project’s needs. Balance of Plant (BOP) The right auxiliary equipment is of critical importance in ensuring that a power solution is economically feasible and provides your business with reliability, availability, and efficiency. Click on the provided BOP options to learn more. Reach out to our experts to select the configuration that fits your business’ needs. Available BOP elements may vary, depending on the engine and application type. Link 1 Activated carbon absorber Link 2 Gas train Link 3 SCR & Oxidation catalyst box Link 6 Exhaust gas heat exchanger Link 8 Control solutions Link 7 Cooling system (radiators) Link 4 CL.AIR - Exhaust gas treatment Link 5 Exhaust gas silencer Link Activated carbon absorber Link Gas train Link SCR & Oxidation catalyst box Link Exhaust gas heat exchanger Link Control solutions Link Cooling system (radiators) Link CL.AIR - Exhaust gas treatment Link Exhaust gas silencer Engine Type Sheet 4 Factsheets Engine Type Sheet 4 100% H2 Factsheets Engine Type Sheet 4 HH Factsheets Deutsche Börse Case Studies Concord Adela Case Studies Customer-only Resources Get access to almost 2,000 Resources (such as Drawings, Service Technician Instructions, User Manuals, & more…) for Jenbacher Gas Engines with our dedicated Portal which includes advanced (yet easy to use!) search capabilities to find what you’re looking for. Subscribe to our monthly Services Newsletter and additional materials to stay up-to-date with the latest Jenbacher technical news. If you already have an access, please LOG IN or Contact Us to Sign-up Type 4 Case studies Los Toldos (ARG) UNBLOCK COMPUTING TURNS FLARE GAS INTO POWER AND PROFIT Repurposing associated petroleum gas supports decarbonization and drives new revenue streams 1 Location Los Toldos II Este, Argentina Installed engines 8 x J420 Electrical output 12 MW Energy source Flare gas Commissioned 2023 Learn more Holzheim (GER) Smart, future focused energy supply Location Holzheim, Germany Installed engines 2 x J420 Electrical output 4.48 MWe Thermal output 4.52 MWt Energy source Biogas Commissioned 2025 Learn more Dettenhausen (GER) MUNICIPAL HEAT GENERATION THAT LEADS BY EXAMPLE thanks to a partnership between industry and municipal utilities Location Dettenhausen, Germany Installed engines 1 x J416 Electrical output 999 kW Thermal output 1,232 kW Energy source Natural gas Commissioned 2021 Learn more RAG Austria (AUT) GREEN ENERGY YEAR ROUND Harnessing the summer sun for winter energy using a Jenbacher hydrogen solution Location Gampern, Austria Installed engines 1 x J412 Electrical output 530 kW Thermal output 550 kW Total efficiency 80.4% Energy source Green hydrogen, alternatively natural gas Commissioned June 2024 Learn more Hyosung (KOR) DECARBONIZING HEAVY INDUSTRY with Asia Pacific’s first 100% hydrogen engine power plant Location Ulsan, South Korea Installed engines 1 x J420 Electrical output up to 1,042 kW Thermal output 1,136 kW Energy source 100% hydrogen Commissioned 2024 Learn more La Cira (COL) TURNING FLARE GAS INTO POWER for lower energy costs, greater reliability, and reduced emissions Location La Cira, Colombia Installed engines 11 x J420 Electrical output 14.6 MW Electrical efficiency 40.8% Energy source Flare gas Commissioned 2016, 2022 Learn more Los Toldos (ARG) Holzheim (GER) Dettenhausen (GER) RAG Austria (AUT) Hyosung (KOR) La Cira (COL) Los Toldos (ARG) UNBLOCK COMPUTING TURNS FLARE GAS INTO POWER AND PROFIT Repurposing associated petroleum gas supports decarbonization and drives new revenue streams 1 Location Los Toldos II Este, Argentina Installed engines 8 x J420 Electrical output 12 MW Energy source Flare gas Commissioned 2023 Learn more Holzheim (GER) Smart, future focused energy supply Location Holzheim, Germany Installed engines 2 x J420 Electrical output 4.48 MWe Thermal output 4.52 MWt Energy source Biogas Commissioned 2025 Learn more Dettenhausen (GER) MUNICIPAL HEAT GENERATION THAT LEADS BY EXAMPLE thanks to a partnership between industry and municipal utilities Location Dettenhausen, Germany Installed engines 1 x J416 Electrical output 999 kW Thermal output 1,232 kW Energy source Natural gas Commissioned 2021 Learn more RAG Austria (AUT) GREEN ENERGY YEAR ROUND Harnessing the summer sun for winter energy using a Jenbacher hydrogen solution Location Gampern, Austria Installed engines 1 x J412 Electrical output 530 kW Thermal output 550 kW Total efficiency 80.4% Energy source Green hydrogen, alternatively natural gas Commissioned June 2024 Learn more Hyosung (KOR) DECARBONIZING HEAVY INDUSTRY with Asia Pacific’s first 100% hydrogen engine power plant Location Ulsan, South Korea Installed engines 1 x J420 Electrical output up to 1,042 kW Thermal output 1,136 kW Energy source 100% hydrogen Commissioned 2024 Learn more La Cira (COL) TURNING FLARE GAS INTO POWER for lower energy costs, greater reliability, and reduced emissions Location La Cira, Colombia Installed engines 11 x J420 Electrical output 14.6 MW Electrical efficiency 40.8% Energy source Flare gas Commissioned 2016, 2022 Learn more Find all Jenbacher Case Studies Other Engine Types JENBACHER TYPE 2 JENBACHER TYPE 3 JENBACHER TYPE 4 JENBACHER TYPE 6 JENBACHER TYPE 9 Our Services Link Jenbacher Services Bringing proven outcomes across the life cycle of your gas engines means less unplanned downtime, greater workforce efficiency, and lower operating costs. From commissioning to overhauling, our global network of qualified service experts provides the support you need, when you need it, by providing the latest technology. Link Remote Monitoring & Optimization Discover how partnering with digital technology can make your business life easier. Link Jenbacher myplant Performance Solution Our cloudbased technology lets you manage your assets wherever you are, secure and live. Take control of the operating performance and profitability of your gas engine by giving it a digital life. FIND MORE SERVICES Consult an expert Send us a message and we’ll contact you to start the conversation. Whether your business is looking for onsite power solutions, access to electricity, decreased energy costs, or even to sell electricity back to your local grid/consumers, Jenbacher regional experts can advise you on which solution makes the most sense for you. CONTACT US Jenbacher J412 Electrical Output up to 935 kW Thermal Output up to 1114 kW Voltage 400V, 6.3kV, 10.5kV Electrical Efficiency up to 43.6 % Thermal Efficiency up to 50.3 %