Verified product-page source (readable static HTML text snapshot)
Source: https://h-cpc.cat.com/cmms/v2?&f=product&it=product&cid=402&lid=en&sc=AE&gid=18327284&pid=15969827&nc=1
Original HTML SHA-256: b0a279a2e8f48e37a1b233e0d02b98bd6b95a6c83635b22eadd77afe5d4f71dc
/ Power Systems / Electric Power / Gas Generator Sets
CG260-16
CG260-16
Overview
Specifications
Equipment
View 360
Overview
From natural gas-fueled combined heat and power (CHP) systems and emergency power for facilities, to renewable biogas energy to support the local grid, or electricity generated from coal mine gases, Caterpillar has a wide range of reliable gas power solutions.
To watch these videos, you will need to accept the use of targeting cookies. Cookies
Specifications
Units: US
Continuous Rating 4500 / 4050 ekW @1.0pf
Fuel Type Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency 44.60 / 44.3%
See more
Docs & Links
Gas Generator Set 50 and 60 Hz Ratings Guide
CG260 Model Series Brochure
Electric Power Ratings Guide
To watch these videos, you will need to accept the use of targeting cookies. Cookies
Docs & Links
Gas Generator Set 50 and 60 Hz Ratings Guide
CG260 Model Series Brochure
Electric Power Ratings Guide
October 27, 2026
Specifications
Units: US
Generator Set Specifications
Continuous Rating 4500 / 4050 ekW @1.0pf
Fuel Type Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency 44.60 / 44.3%
Maximum Standby Rating 4500 ekW
Frequency 50 / 60 Hz
RPM 1000 / 900 rpm
Engine Specifications
Engine Model CG260-16
Displacement 16586 in³
Stroke 12.6 in
Bore 10.2 in
Aspiration TA
Generator Set Dimensions
Length 371 in
Width 110 in
Height 133 in
Dry Weight - Genset 117505 lb
Benefits & Features
Data not available.
Standard Equipment
Air Inlet
One-element single-stage air cleaner with enclosure and sevice indicator
Turbocharger with a water-cooled bearing case for all cylinder
Control Panels
TEM (Total Electronic Management)
Cooling
flange connections for JW inlet and outlet
Jacket water and SCAC thermostats
Electrical jacket water and aftercooler coolant pump
Exhaust
Closed crankcase ventilation system
Exhaust waste gate for the CG260-16
Fuel system
Pre-chamber spark plugs
Independently controlled cylinder monitoring and ignition system
Electronic fuel metering valve
Generator
Reactive droop
3-phase sensing and KVAR/PF control
Winding temperature detectors
Grid code generator
Anti-condensation space heater
Closed-coupled generator result in no torque transmission to the base frame
Busbar connections
Starting/Charging
Compressed air engine start
General
Crankshaft vibration damper and guard
Optional Equipment
Cooling
CHP skid
Grid Code Compliance
50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands
Related Products
Units: US
View 360