Verified product-page source (readable static HTML text snapshot) Source: https://www.jenbacher.com/en/gas-engines/type-6/j616/ Original HTML SHA-256: da44397ec6266d3749e57c4d89d046465cd59567b1d3d94303e772fd6084bcb6 Other Engine Types Jenbacher J616 Details Balance of Plant Case Studies A V16-cylinder high-density power solution. With electrical efficiency up to 45.7%. The J616 is widely used by medium and big size businesses across variety of industries around the globe. Back to Jenbacher Type 6 Other Type 6 models: j612 / up to 2,092 kW j620 fast start / 3,114 kW j620 / up to 3,509 kW j624 / up to 4,499 kW Genset CHP Module Container Change the scope of supply by clicking on a thumbnail. Scope of supply: Generator Set CHP Module Container * Provided technical data is for information only. Data ranges are calculated considering various gas quality levels and ambient conditions (standard or hot/tropical conditions, etc.). Jenbacher can change the technical data unilaterally. In the case of such change, we will update the data on our pages as soon as we can. Please reach out to our experts to get help with engines selection, obtain the technical parameters for your gas composition. Output and efficiency at generator terminals. Energy input is according to DIN ISO 3046 and DIN 6271, respectively, with a tolerance of + 5%. All data according to full load and subject to technical development and modification. Based on emission values of 250 and 500 mg/Nm3 NOx at 5% O2 at dry exhaust gas. Base for biogas and sewage gas versions: 65% CH4 / 35% CO 2 . Base for landfill gas version: 55% CH4 / 40% CO 2 / Rest N2. 50 Hz 60 Hz - Any Fuel Type - Bio-, Sewage-, Landfill Gas Coal Mine Gas Natural Gas Associated Petroleum Gas (Flaregas) Electrical Output up to 2,797 kW Thermal Output up to 2,906 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 45.7 % Thermal Efficiency up to 47.0 % Electrical Output up to 2,677 kW Thermal Output up to 2,432 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 44.8 % Thermal Efficiency up to 41.4 % Electrical Output up to 2,677 kW Thermal Output up to 2,789 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 43.7 % Thermal Efficiency up to 44.7 % Electrical Output up to 2,797 kW Thermal Output up to 2,906 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 45.7 % Thermal Efficiency up to 47.0 % Electrical Output up to 2,432 kW Thermal Output up to 2,578 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 43.3 % Thermal Efficiency up to 45.6 % L: 8,300 x W: 2,200 x H: 3,000 mm - Any Fuel Type - Bio-, Sewage-, Landfill Gas Coal Mine Gas Natural Gas Associated Petroleum Gas (Flaregas) Electrical Output up to 2,779 kW Thermal Output up to 2,906 kW Voltage 480V - 13.8kV Electrical Efficiency up to 45.5 % Thermal Efficiency up to 47.0 % Electrical Output up to 2,662 kW Thermal Output up to 2,432 kW Voltage 480V - 13.8kV Electrical Efficiency up to 44.5 % Thermal Efficiency up to 41.4 % Electrical Output up to 2,677 kW Thermal Output up to 2,789 kW Voltage 480V - 13.8kV Electrical Efficiency up to 43.7 % Thermal Efficiency up to 44.7 % Electrical Output up to 2,779 kW Thermal Output up to 2,906 kW Voltage 480V - 13.8kV Electrical Efficiency up to 45.5 % Thermal Efficiency up to 47.0 % Electrical Output up to 2,420 kW Thermal Output up to 2,578 kW Voltage 480V - 13.8kV Electrical Efficiency up to 43.1 % Thermal Efficiency up to 45.6 % L: 400 x W: 90 x H: 118 inches 50 Hz 60 Hz - Any Fuel Type - Bio-, Sewage-, Landfill Gas Coal Mine Gas Natural Gas Associated Petroleum Gas (Flaregas) Electrical Output up to 2,797 kW Thermal Output up to 2,906 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 45.7 % Thermal Efficiency up to 47.0 % Electrical Output up to 2,677 kW Thermal Output up to 2,432 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 44.8 % Thermal Efficiency up to 41.4 % Electrical Output up to 2,677 kW Thermal Output up to 2,789 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 43.7 % Thermal Efficiency up to 44.7 % Electrical Output up to 2,797 kW Thermal Output up to 2,906 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 45.7 % Thermal Efficiency up to 47.0 % Electrical Output up to 2,432 kW Thermal Output up to 2,578 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 43.3 % Thermal Efficiency up to 45.6 % L: 8,300 x W: 2,200 x H: 3,000 mm - Any Fuel Type - Bio-, Sewage-, Landfill Gas Coal Mine Gas Natural Gas Associated Petroleum Gas (Flaregas) Electrical Output up to 2,779 kW Thermal Output up to 2,906 kW Voltage 480V - 13.8kV Electrical Efficiency up to 45.5 % Thermal Efficiency up to 47.0 % Electrical Output up to 2,662 kW Thermal Output up to 2,432 kW Voltage 480V - 13.8kV Electrical Efficiency up to 44.5 % Thermal Efficiency up to 41.4 % Electrical Output up to 2,677 kW Thermal Output up to 2,789 kW Voltage 480V - 13.8kV Electrical Efficiency up to 43.7 % Thermal Efficiency up to 44.7 % Electrical Output up to 2,779 kW Thermal Output up to 2,906 kW Voltage 480V - 13.8kV Electrical Efficiency up to 45.5 % Thermal Efficiency up to 47.0 % Electrical Output up to 2,420 kW Thermal Output up to 2,578 kW Voltage 480V - 13.8kV Electrical Efficiency up to 43.1 % Thermal Efficiency up to 45.6 % L: 400 x W: 90 x H: 118 inches 50 Hz 60 Hz - Any Fuel Type - Bio-, Sewage-, Landfill Gas Coal Mine Gas Natural Gas Associated Petroleum Gas (Flaregas) Electrical Output up to 2,797 kW Thermal Output up to 2,906 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 45.7 % Thermal Efficiency up to 47.0 % Electrical Output up to 2,677 kW Thermal Output up to 2,432 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 44.8 % Thermal Efficiency up to 41.4 % Electrical Output up to 2,677 kW Thermal Output up to 2,789 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 43.7 % Thermal Efficiency up to 44.7 % Electrical Output up to 2,797 kW Thermal Output up to 2,906 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 45.7 % Thermal Efficiency up to 47.0 % Electrical Output up to 2,432 kW Thermal Output up to 2,578 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 43.3 % Thermal Efficiency up to 45.6 % L: 12,000 - 20,500 x W: 3,000 - 6,000 x H: 3,800 - 15,000 mm - Any Fuel Type - Bio-, Sewage-, Landfill Gas Coal Mine Gas Natural Gas Associated Petroleum Gas (Flaregas) Electrical Output up to 2,779 kW Thermal Output up to 2,906 kW Voltage 480V - 13.8kV Electrical Efficiency up to 45.5 % Thermal Efficiency up to 47.0 % Electrical Output up to 2,662 kW Thermal Output up to 2,432 kW Voltage 480V - 13.8kV Electrical Efficiency up to 44.5 % Thermal Efficiency up to 41.4 % Electrical Output up to 2,677 kW Thermal Output up to 2,789 kW Voltage 480V - 13.8kV Electrical Efficiency up to 43.7 % Thermal Efficiency up to 44.7 % Electrical Output up to 2,779 kW Thermal Output up to 2,906 kW Voltage 480V - 13.8kV Electrical Efficiency up to 45.5 % Thermal Efficiency up to 47.0 % Electrical Output up to 2,420 kW Thermal Output up to 2,578 kW Voltage 480V - 13.8kV Electrical Efficiency up to 43.1 % Thermal Efficiency up to 45.6 % L: 475 - 810 x W: 120 - 240 x H: 150 - 590 inches CONSULT AN EXPERT Back to Jenbacher Type 6 Other Type 6 models: j612 / up to 2,092 kW j620 fast start / 3,114 kW j620 / up to 3,509 kW j624 / up to 4,499 kW Product Details Resources Type 6 engines are loaded with features that support heat recovery, help provide stable combustion, reduce emissions, and increase efficiency under defined operating conditions — supporting strong performance across the Jenbacher product line. A centrally-located purged pre-combustion chamber helps provide suitable ignition conditions. The spark plug ignition energy is amplified in the pre-combustion chamber, which can support stable and reliable combustion. Miller valve timing can help reduce compression temperature and increase the margin to knocking limits, supporting improved ignition timing and efficient operation. A super fit for any type of application, from peaking to baseload. Scope of supply: Generator Set CHP Module Container Scope of supply, dedicated for applications, which require power generation only. If you are looking for simultaneous power and heat generation, please consider Combined Heat and Power Module ( CHP Module ) scope of supply. Minimum scope of supply for genset: Engine and alternator installed on the frame Control panel Gas train The scope of supply can be extended further with various balance of plant options (BOP), reach out to our specialists for help in selecting scope of supply and BOP options to fulfill your project’s needs. Gensets can be installed inside a building or inside a container. To see more details about our containerized solutions, click here . Combined Heat and Power Module ( CHP Module ) solutions allow customers to generate power and heat simultaneously at a high total efficiencies, reaching up to 95%. Usual scope of supply: Engine and alternator installed on the frame Control panel, gas train Heat exchangers including exhaust gas heat exchanger CHP Modules can generate hot water or steam at various parameters and can be integrated with your existing heat infrastructure. You can select the option that fits your project’s needs among the various heat recovery schemes provided by Jenbacher. The scope of supply can be extended further with various balance of plant options (BOP), reach out to our specialists for help in selecting scope of supply and BOP options to fulfill your project’s needs. CHP Modules can be installed inside a building or inside a container. To see more details about Jenbacher’s containerized solutions, click here . Jenbacher’s containerized solutions are “ready-to-use” power plants, allowing customers to minimize commissioning time. Jenbacher has produced containerized power plants, allowing customers to reduce commissioning time. Jenbacher has produced containerized power plant solutions for decades, providing customers with innovative power generation technologies wrapped in well-designed, dependable packages. Both genset and CHP module solutions can be supplied as containerized versions depending on your needs. Usual scope of supply: Engine and alternator installed on the frame Control panel, gas train Container with integrated ventilation system Cooling systems Lube oil supply system Exhaust gas heat exchanger (for CHP module) The scope of supply can be extended further with various balance of plant options (BOP), reach out to our specialists for help in selecting scope of supply and BOP options to fulfill your project’s needs. Balance of Plant (BOP) The right auxiliary equipment is of critical importance in ensuring that a power solution is economically feasible and provides your business with reliability, availability, and efficiency. Click on the provided BOP options to learn more. Reach out to our experts to select the configuration that fits your business’ needs. Available BOP elements may vary, depending on the engine and application type. Link 1 Activated carbon absorber Link 2 Gas train Link 3 SCR & Oxidation catalyst with silencer Link 5 Exhaust gas heat exchanger Link 7 Control solutions Link 6 Cooling system (radiators) Link 4 Exhaust gas silencer Link Activated carbon absorber Link Gas train Link SCR & Oxidation catalyst with silencer Link Exhaust gas heat exchanger Link Control solutions Link Cooling system (radiators) Link Exhaust gas silencer Engine Type Sheet 6 Factsheets Engine Type Sheet 6 HH Factsheets Customer-only Resources Get access to almost 2,000 Resources (such as Drawings, Service Technician Instructions, User Manuals, & more…) for Jenbacher Gas Engines with our dedicated Portal which includes advanced (yet easy to use!) search capabilities to find what you’re looking for. Subscribe to our monthly Services Newsletter and additional materials to stay up-to-date with the latest Jenbacher technical news. If you already have an access, please LOG IN or Contact Us to Sign-up Type 6 Case studies STAWAG (GER) THE JENBACHER EMISSIONS REDUCTION PACKAGE for full control over your exhaust gas levels Location Aachen, Germany Installed engines 5 x J624 Electrical output 22.1 MW Thermal output 23.6 MW Energy source Natural gas Commissioned 2022 Learn more Bad Reichenhall (GER) SUSTAINABLE HEAT SUPPLY with innovative, intelligently controlled cogeneration of heat and power Location Bad Reichenhall, Germany Installed engines 2 x J620 Electrical output 3.4 MW Thermal output 3.2 MW Energy source Natural gas Commissioned 2022 Learn more BOPP Barranquilla (COL) DELIVERING RELIABLE AND EFFICIENT ELECTRICITY, HEAT, AND COLD WATER Trigeneration solution for plastic industry Location Barranquilla, Colombia Installed engines 3 x J624 Electrical output 4,379 MW Thermal output 2,548 MW Total efficiency 70.6% Energy source Natural gas Commissioned 2020, 2021, 2023 Learn more El Gabar Al Asfar Wastewater Treatment Plant (EGY) EL GABAL AL ASFAR SEWAGE GAS PLANT boosts power and cuts costs at one of Egypt’s largest wastewater treatment facilities Location Cairo, Egypt Installed engines 6 x J616 Electrical output 14.6 MW Thermal output 7.5 MW Total efficiency 65.9% Energy source Sewage gas Commissioned 2024 Learn more Biohof Querdel (GER) RENEWABLE STORAGE POWER PLANT A contribution to the energy transition in Germany Location Münsterland, Germany Installed engines 3 x J620 Electrical output 3 x 3.35 MW Thermal output 3 x 3.54 MW Energy source Biomethane Commissioned 2023 Learn more CN Paper Mill (CHN) USING WASTEWATER SEWAGE GAS TO PROVIDE ELECTRICITY AND HEAT FOR PAPER MILL IN CHINA Solution reduces costs while converting waste to energy Location China Installed engines 3 x J616 Electrical output 8,028 kW Thermal output 7,562 kW Energy source Sewage gas Commissioned 2023 Learn more STAWAG (GER) Bad Reichenhall (GER) BOPP Barranquilla (COL) El Gabar Al Asfar Wastewater Treatment Plant (EGY) Biohof Querdel (GER) CN Paper Mill (CHN) STAWAG (GER) THE JENBACHER EMISSIONS REDUCTION PACKAGE for full control over your exhaust gas levels Location Aachen, Germany Installed engines 5 x J624 Electrical output 22.1 MW Thermal output 23.6 MW Energy source Natural gas Commissioned 2022 Learn more Bad Reichenhall (GER) SUSTAINABLE HEAT SUPPLY with innovative, intelligently controlled cogeneration of heat and power Location Bad Reichenhall, Germany Installed engines 2 x J620 Electrical output 3.4 MW Thermal output 3.2 MW Energy source Natural gas Commissioned 2022 Learn more BOPP Barranquilla (COL) DELIVERING RELIABLE AND EFFICIENT ELECTRICITY, HEAT, AND COLD WATER Trigeneration solution for plastic industry Location Barranquilla, Colombia Installed engines 3 x J624 Electrical output 4,379 MW Thermal output 2,548 MW Total efficiency 70.6% Energy source Natural gas Commissioned 2020, 2021, 2023 Learn more El Gabar Al Asfar Wastewater Treatment Plant (EGY) EL GABAL AL ASFAR SEWAGE GAS PLANT boosts power and cuts costs at one of Egypt’s largest wastewater treatment facilities Location Cairo, Egypt Installed engines 6 x J616 Electrical output 14.6 MW Thermal output 7.5 MW Total efficiency 65.9% Energy source Sewage gas Commissioned 2024 Learn more Biohof Querdel (GER) RENEWABLE STORAGE POWER PLANT A contribution to the energy transition in Germany Location Münsterland, Germany Installed engines 3 x J620 Electrical output 3 x 3.35 MW Thermal output 3 x 3.54 MW Energy source Biomethane Commissioned 2023 Learn more CN Paper Mill (CHN) USING WASTEWATER SEWAGE GAS TO PROVIDE ELECTRICITY AND HEAT FOR PAPER MILL IN CHINA Solution reduces costs while converting waste to energy Location China Installed engines 3 x J616 Electrical output 8,028 kW Thermal output 7,562 kW Energy source Sewage gas Commissioned 2023 Learn more Find all Jenbacher Case Studies Other Engine Types JENBACHER TYPE 2 JENBACHER TYPE 3 JENBACHER TYPE 4 JENBACHER TYPE 6 JENBACHER TYPE 9 Our Services Link Jenbacher Services Bringing proven outcomes across the life cycle of your gas engines means less unplanned downtime, greater workforce efficiency, and lower operating costs. From commissioning to overhauling, our global network of qualified service experts provides the support you need, when you need it, by providing the latest technology. Link Remote Monitoring & Optimization Discover how partnering with digital technology can make your business life easier. Link Jenbacher myplant Performance Solution Our cloudbased technology lets you manage your assets wherever you are, secure and live. Take control of the operating performance and profitability of your gas engine by giving it a digital life. FIND MORE SERVICES Consult an expert Send us a message and we’ll contact you to start the conversation. Whether your business is looking for onsite power solutions, access to electricity, decreased energy costs, or even to sell electricity back to your local grid/consumers, Jenbacher regional experts can advise you on which solution makes the most sense for you. CONTACT US Jenbacher J616 Electrical Output up to 2,797 kW Thermal Output up to 2,906 kW Voltage 690V, 6.3kV, 10.5kV, 11KV Electrical Efficiency up to 45.7 % Thermal Efficiency up to 47.0 %