Verified product-page source (readable static HTML text snapshot) Source: https://h-cpc-stage.cat.com/cmms/v2?f=product&it=product&cid=402&lid=en&sc=US&gid=18260932&pid=18331497&nc=1 Original HTML SHA-256: a7c7afa100e486aa612a09bbc7003fb1f3a5f3a891a7f75cd3d5649d3f351236 / Power Systems / Electric Power / Diesel Generator Sets C27 (60 Hz) C27 (60) Overview Specifications Benefits & Features Equipment Related Products Overview The C27 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 680 to 800 ekW at 60 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and to take on 100% block load. The C27 is certified as a low fuel consumption system as well as having a certificate for EPA Stationary Emergency (Tier 2). Seismic certification is also available for selected models, ensuring your generator sets are equipped for that unexpected disturbance. The integrated control system, including ATS and switchgear, ensures a consistent power supply and connection to your fleet through on-site and remote monitoring options. The GCCP 1.2 control panel features a user-friendly interface and puts your management and diagnostics tools in one location. The optional ECS 200 controller provides multi generator set paralleling capability, allowing you to use multiple generator sets for increased power output and improved reliability. It's not just quality that matters but customization, choose from a broad range of accessories and bolt-on system expansion attachments. Discover our upgradeable packaging options to work with your spatial restrictions and environmental conditions. Our C27 generator sets are developed for such prerequisites, so that you can meet your specific power needs. Build in additional safety features with the UL 2200 (3rd Edition) and CSA certified package options. To watch these videos, you will need to accept the use of targeting cookies. Cookies Specifications Units: US Standby Rating 750/800 ekW Prime Power Rating 680/725 ekW Emissions/Fuel Strategy Low BSFC / U.S. EPA Tier 2 Certified See more Benefits & Features Cat Generator Set Package Cat generator set packages have been fully prototype tested Accepts 100% block load and meets NFPA 110 loading requirements with G3 Class load acceptance capability Conform to ISO 8528-5 steady state and transient response requirements Cat Diesel Engine Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight SR5 Alternator Superior motor starting capability minimizes need for oversizing alternator Designed to match performance and output characteristics of Cat diesel engines Robust Class H insulation See more Docs & Links Electric Power Ratings Guide C27, 60 Hz, 750 ekW Standby 680 ekW Prime, Low Fuel Consumption Spec Sheet C27, 60 Hz, 750 ekW Standby 680 ekW Prime, U.S. EPA Emergency Stationary (Tier 2) Spec Sheet C27 Electric Power Ratings To watch these videos, you will need to accept the use of targeting cookies. Cookies Docs & Links Electric Power Ratings Guide C27, 60 Hz, 750 ekW Standby 680 ekW Prime, Low Fuel Consumption Spec Sheet C27, 60 Hz, 750 ekW Standby 680 ekW Prime, U.S. EPA Emergency Stationary (Tier 2) Spec Sheet C27 Electric Power Ratings October 27, 2026 Specifications Units: US Generator Set Specifications Standby Rating 750/800 ekW Prime Power Rating 680/725 ekW Emissions/Fuel Strategy Low BSFC / U.S. EPA Tier 2 Certified Voltage 208 to 600 Volts Frequency 60 Hz Speed 1800 rpm Duty Cycle Standby, Prime Engine Specifications Engine Model C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Bore 5.4 in Stroke 6 in Displacement 1649.47 in³ Compression Ratio 16.1:1 Aspiration TA Fuel System MEUI Governor Type Adem™A4 Generator Set Dimensions Length - Maximum 184 in Width - Maximum 67.8 in Height - Maximum 85.1 in Benefits & Features Cat Generator Set Package Cat generator set packages have been fully prototype tested Accepts 100% block load and meets NFPA 110 loading requirements with G3 Class load acceptance capability Conform to ISO 8528-5 steady state and transient response requirements Cat Diesel Engine Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight SR5 Alternator Superior motor starting capability minimizes need for oversizing alternator Designed to match performance and output characteristics of Cat diesel engines Robust Class H insulation GCCP and CAT ECS User-friendly interface and navigation Scalable system to meet a wide range of installation requirement Expansion modules and site-specific programming for specific customer requirements Cooling System Designed to operate in standard ambient temperatures up to 55°C (131°F) Contact your Cat Dealer for specific ambient and altitude capabilities Certifications UL 2200 CSA IBC seismic certification OSHPD pre-approval One Safe Source Components used in the generator set are selected based on seamless design integration to provide the optimum performance The generator set is fully assembled at a Caterpillar facility following our quality guidelines Each generator set package is tested before leaving the Caterpillar facility Cat product support, including dealer service, parts and warranty covers the entire Cat power system Worldwide Product Support Cat dealers have over 1,800 dealer branch stores operating in 200 countries Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements Standard Equipment Air Inlet Air cleaner; single element canister type with service indicator Control Panel GCCP 1.2 Digital Indicators Warning/shutdown Indicators Programmable protective relaying functions Communications Features include: Cooling System Coolant level sensor Coolant drain line with valve terminated on edge of base ATAAC Caterpillar extended life coolant Radiator sized to 50 degrees C Fan and belt guards drive Exhaust System 203 mm (8 in) ID round flanged outlet Exhaust manifold - dry Fuel System Primary fuel filter with integral water separator Electric fuel priming pump Fuel cooler Flexible fuel lines - installed Secondary fuel filters Generators and Attachments Integrated voltage regulator (IVR) includes For EPA Stationary Emergency (EPA Tier 2 Emissions) configurations: Busbar connections: SR5 Permanent magnet excitation (PMG) (PM) For Low BSFC configurations: Lube System Standard volume oil pan - 68 Ltr Lubricating oil Oil drain lines and valve Gear type lube oil pump Oil filter, filler and dipstick Fumes disposal - open crankcase ventilation routed to front of package Integral lube Oil cooler Mounting System Rubber anti-vibration mounts - shipped loose Rails - engine/generator/radiator mounting Starting and Charging System 24-Volt electric starting motor Battery, rack and cables - shipped-loose Battery disconnect switch Charging alternator 45A General Paint - Caterpillar yellow with high gloss black rails & radiator SAE standard rotation Right hand servicing Flywheel and flywheel housing-SAE No. 0 and SAE No. 18 Optional Equipment Air Inlet System Standard air cleaners Heavy duty air cleaners Dual element air cleaners Starting / Charging System 20 Amp enclosure Battery chargers 10 Amp Battery chargers 24 Volt battery set - Dry Air starting motor with control and silencer Space heater 24 Volt electric start motors - Heavy duty Jacket water heaters Circuit breakers 400, 800, 1200, 1600, 2000, 2500, 3000 Amp, 3 pole, UL-100% rated Circuit breakers 2000 Amp, 3 pole, IEC rated Circuit breakers 800 Amp, 4 pole, IEC rated Circuit breakers Control Panels Cable shroud - Bottom mounted Cable shroud - Top mounted CAT ECS 200 Side extension box Remote annunciator module Auxiliary box options Remote mounted panel harness mounting kit Remote mounted circuit breaker terminals Modbus monitor local packages Remote DIO module Cat connect telematics Load share module Vandal proof panel cover Installed DIO module Remote mounting harness Annunciator modules Cooling System Radiator duct flange High ambient radiator Extended life coolant Certified radiator Standard radiator Enclosures Enclosure louvers Enclosure with lifting base or fuel tank Panel bracket AC distribution panel, lights and outlet Enclosure lighting Enclosure colors Special Sound attenuated enclosure Enclosure fuel tank options Cold weather bundle Exhaust System Mufflers Elbows Flanges Exhaust through the wall kit Flexible fittings Guard and shield system Generator and Attachments 60 Hz standard generators 60 Hz premium generators Lube System Prelube pumps Oil level regulator Mounting System Mounting base type IBC vibration isolators Puck style low efficiency isolators Spring type vibration isolators Power Connections Center post busbars Cable entry - right/left/rear Neutral grounding connection Power connections - Right / Left / Rear Special Tests / Reports Torsional vibration analysis report Generator test report IBC seismic Certifications OSHPD seismic Certifications PGS Test report @ 1.0 power factor PGS Test report @ 0.8 power factor Special CSA test Certification Standard engine test General Miscellaneous inspection US aid emblem Special paint SGS Inspection Related Products Units: US Electric Power Controls Model EMCP 4.2 Control Panel View 360