Verified product-page source (readable static HTML text snapshot)
Source: https://powergenserv.com/equipment/generators/gillette/pr-1800/
Original HTML SHA-256: 60de2dca11f1b09a33f8e06886ec863ac059a29b1790029d68811ef9ed737bce
Overview #
The Gillette PR-1800 is a 180-kilowatt prime-rated natural gas generator on PSI's 11.1L turbocharged inline-6 — a displacement unique to the prime series. This engine sits between the 8.1L (PR-1000/1300) and the 14.6L (PR-2400), delivering 272 bhp at 180 kW prime. Stamford UCID274J alternator, DSE 7420 MKII controller.
The PSI 11.1L — a prime-specific displacement #
The 11.1L inline-6 does not appear in the SP standby series. PSI offers this displacement specifically for continuous-duty applications where the 8.1L is undersized but the 14.6L is over-specified. At 180 kW prime from 11.1L, the engine runs at comfortable specific loading for sustained duty.
Our service experience #
The PSI 11.1L prime gas engine is less common than the 8.8L V8 in our territory but follows the same PSI service protocols. For continuous-duty installations, we establish structured maintenance contracts with defined 250-hour oil change windows.
Engineering specifications
Physical
Length 132 in
Width 52 in
Height 80 in
Wet weight 6,375 lb
Acoustic
Sound @ 7m, full load 75 dBA
Enclosure Sound-attenuated
Fuel system & runtime
BTU/hr @ full load 1,980,000
Photos
Documents & downloads
Spec sheets & manuals
Spec sheet (datasheet)
Service manual
Controller manual
Alternator manual
Ready to order this model?
Configure your Gillette PR-1800
Lock the enclosure, fuel system, transfer switch, and add-ons — we'll confirm pricing, availability, and lead time within one business day. Prefer a free-form quote? That option is still here.
Configure & Quote → Just request a quote Download datasheet
Estimate runtime for the Gillette PR-1800
Adjust load percent and tank size to estimate runtime. Pre-filled with this model's spec where available.
Estimate runtime on this tank
Generator size
kW
Fuel
Diesel Natural Gas
Load
25 % load 50 % load 75 % load 100 % load
Fuel demand at 75 % load
1,890,000 BTU/hr ≈ 1890.0 cf/min @ 1,000 BTU/cf
On utility natural gas the runtime is generally unlimited provided the supply line and meter can deliver this BTU/hr at the engine's required inlet pressure (typically 5–14" WC residential, up to 5 psi commercial). Confirm against the OEM's published fuel-pressure spec.
Service intervals
Manufacturer-recommended intervals for the Gillette PR-1800 under standby duty. Field intervals may differ based on load profile, ambient conditions, and fuel quality.
Oil & filter Every 250 hours or 6 months
Coolant change Every 4000 hours
Air filter Every 500 hours
Spark plugs Every 1000 hours
Major overhaul ≈ 15,000 hours
Load bank test Every 12 months
Common failure modes
What we've seen fail on this platform. Use as a service-planning reference, not a diagnostic — actual failure modes depend heavily on duty cycle and maintenance history.
Component Symptom Typical hours Severity
Turbocharger Power loss from continuous duty wear 10,000+ moderate
Spark plugs / ignition Misfire, rough running 1,000+ moderate
Charge air cooler Elevated intake temps, reduced output 8,000+ moderate
Frequently Asked Questions
What engine does the PR-1800 use? PSI 11.1L turbocharged inline-6 — a displacement unique to the PR prime series (not used in the SP standby lineup). At 674 cu in, this sits between the 8.1L I6 (PR-1000/1300) and the 14.6L V8 (PR-2400). The inline-6 architecture provides smooth, balanced operation for sustained continuous duty at 272 bhp.
What fuel consumption at 180 kW prime? 1,980 ft3/hr NG at full load. At 75%: 1,500 ft3/hr. At 50%: 1,075 ft3/hr. Verify gas utility capacity for continuous-duty demand — 180 kW prime draws gas 24/7, not just during outages.
Compatible equipment
Controllers
DSE 7420 MkII Controllers
Transfer switches
ASCO 300 Series ATS Automatic Transfer Switches
ASCO 7000 Series Transfer Switch Automatic Transfer Switches
Eaton ATC-900 Automatic Transfer Switches
Thomson TS840 Automatic Transfer Switch Automatic Transfer Switches
Thomson TS870 Automatic Transfer Switch Automatic Transfer Switches
More in the PR Series (Prime Gas)
80–540 kW natural gas prime power on PSI engines — continuous duty for remote sites, mining, and off-grid operations.
View all 7 models in this series →
Why we recommend Gillette
When budget and lead time matter for industrial diesel standby, we recommend Gillette. Same John Deere and Volvo engines as the major brands, same UL-2200 certification, same Deep Sea Electronics controllers — at 15-30% less, with 3-7 day lead times that the big OEMs can't touch.
We pitch Gillette for industrial diesel applications where buyers prioritize value and open-architecture serviceability. The John Deere and Volvo engines are the same platforms we service daily across other brands, so our technicians maintain Gillette units with full confidence.
See all Gillette generators →
Similar models
Gillette
Gillette PR-1300
Factory-direct prime-rated gas at 15-30% below major brands. PSI 8.1L I6 engine + DSE controller — continuous duty, no lock-in.
130 kW standby · Natural Gas · Liquid-cooled
130 kW prime-rated natural gas generator. PSI 8.1L I6 turbocharged, Stamford UCI274F alternator, DSE 7420 MKII. Continuous duty. Made in USA.
EPA Stationary Spark Ignition 3-phase prime-power remote-site
Compare
Gillette
Gillette PR-2400
Factory-direct prime-rated gas at 15-30% below major brands. PSI 14.6L V8 engine + DSE controller — continuous duty, no lock-in.
240 kW standby · Natural Gas · Liquid-cooled
240 kW prime-rated natural gas generator. PSI 14.6L V8 turbocharged, Stamford S4L1DD alternator, DSE 7420 MKII. Continuous duty, 3-phase only. Made in USA.
EPA Stationary Spark Ignition 3-phase prime-power remote-site
Compare
Gillette
Gillette SP-2000P
Factory-direct at 15-30% below major brands. PSI 8.8L high-output turbo V8 + DSE controller — no proprietary lock-in. 3-7 day lead times.
200 kW standby · Natural Gas · Liquid-cooled
200 kW natural gas stationary standby generator. Made-in-USA commercial unit with PSI 8.8L high-output turbocharged V8, Stamford alternator, and DSE 7420 MKII controller. NG only.
EPA Stationary Spark Ignition 3-phase commercial hotel
Compare
Services for the Gillette PR-1800
Generator Maintenance
Buy a Generator
Need service or parts for the Gillette PR-1800?
We service every major OEM and stock genuine parts for the most common models.
Get A Quote Or call (209) 229-1990
Last reviewed: May 6, 2026